Link to home
Start Free TrialLog in
Avatar of Dragon0x40
Dragon0x40

asked on

How do you tell if you have a FANTRAY2 installed?

How do you tell if you have FANTRAY2 installed?

I want to install a Sup720 line card.

Is there a command or do you physically look at it?
ASKER CERTIFIED SOLUTION
Avatar of beadams76
beadams76

Link to home
membership
This solution is only available to members.
To access this solution, you must be a member of Experts Exchange.
Start Free Trial
Avatar of Dragon0x40
Dragon0x40

ASKER

Looks like I do not have a FAN2 tray.

Fan  Model               Ver Cooling  Ambient FanStatus
                             capacity temp
---- ------------------- --- -------- ------- ---------
1    WS-C6K-13SLOT-FAN     1  641 cfm    -   ok


> (enable) sh env all
Environmental Status (. = Pass, F = Fail, U = Unknown, N = Not Present)
  PS1: .     PS2: .     PS1 Fan: .     PS2 Fan: .
  Chassis-Ser-EEPROM: .     Fan1: .
  Clock(A/B): A         Clock A: .     Clock B: .
  VTT1: .    VTT2: .    VTT3: .

                  Intake          Exhaust         Device 1        Device 2
Slot            Temperature     Temperature     Temperature     Temperature
--------------- --------------- --------------- --------------- ---------------
2               23C(50C,65C)    23C(60C,75C)    24C             21C
3               23C(50C,65C)    22C(60C,75C)    N/A             N/A
4               21C(55C,65C)    25C(55C,70C)    23C(50C,65C)    22C(50C,65C)
5               21C(55C,65C)    26C(55C,70C)    24C(50C,65C)    22C(50C,65C)
9               19C(50C,65C)    22C(60C,75C)    19C             20C
10              22C(50C,65C)    26C(60C,75C)    21C             26C
12              23C(50C,65C)    26C(60C,75C)    21C             24C
13              25C(50C,65C)    29C(60C,75C)    23C             24C
2  (Switch-Eng) 22C(50C,65C)    20C(60C,75C)    N/A             N/A

Chassis Modules
---------------------
VTT1: 24C(85C,100C)
VTT2: 23C(85C,100C)
VTT3: 21C(85C,100C)

PS1 WS-CAC-2500W AC with 1 input(s) and 2 output mode(s)
  Capacity               :
    Mode1                : 1153.32 Watts ( 27.46 Amps @42V)
    Mode2 [operational]  : 2331.00 Watts ( 55.50 Amps @42V)
  Capabilities
    Floating power       : No
    Remote reset         : No
    Input configuration  : No
  Status
    Online               : Yes
    Used                 : Yes
    Output status        : Ok
      PS                 : Ok
      PS Fan             : Ok
    IVM mode             : High AC

PS2 WS-CAC-2500W AC with 1 input(s) and 2 output mode(s)
  Capacity               :
    Mode1                : 1153.32 Watts ( 27.46 Amps @42V)
    Mode2 [operational]  : 2331.00 Watts ( 55.50 Amps @42V)
  Capabilities
    Floating power       : No
    Remote reset         : No
    Input configuration  : No
  Status
    Online               : Yes
    Used                 : Yes
    Output status        : Ok
      PS                 : Ok
      PS Fan             : Ok
    IVM mode             : High AC

PS Configuration : PS1 and PS2 in Redundant Configuration.

Total Power Available                        :  2331.00 Watts ( 55.50 Amps @42V)
Total Power Chassis Limit                    :  7560.00 Watts (180.00 Amps @42V)
Total Power Chassis Recommended              :  7560.00 Watts (180.00 Amps @42V)
Total Power Available for Line Card Usage    :  2264.64 Watts ( 53.92 Amps @42V)
Total Power Drawn From the System            :  1050.42 Watts ( 25.01 Amps @42V)
Total Power Drawn by the Chassis             :    66.36 Watts (  1.58 Amps @42V)
Total Power Drawn by the modules             :   984.06 Watts ( 23.43 Amps @42V)
Total Inline Power Drawn From the System     :     0.00 Watts (  0.00 Amps @42V)
Total Power Reserved as localpool for modules:     0.00 Watt
Remaining Power in the System                :  1280.58 Watts ( 30.49 Amps @42V)
Configured Default Inline Power per port     :     7.00 Watts (  0.17 Amps @42V)

Slot power Requirement/Usage :

Slot Model                   Power Requested Power Allocated CardStatus
                             Watts    A @42V Watts    A @42V
---- ----------------------- -------- ------ -------- ------ ----------
1    (empty supervisor slot)     0.00   0.00   128.52   3.06 none
2    WS-X6K-SUP2-2GE           128.52   3.06   128.52   3.06 ok
3    WS-X6416-GBIC             118.02   2.81   118.02   2.81 ok
4    WS-X6148-GE-TX            103.74   2.47   103.74   2.47 ok
5    WS-X6148-GE-TX            103.74   2.47   103.74   2.47 ok
9    WS-X6348-RJ-45            100.38   2.39   100.38   2.39 ok
10   WS-X6348-RJ-45            100.38   2.39   100.38   2.39 ok
12   WS-X6348-RJ-45            100.38   2.39   100.38   2.39 ok
13   WS-X6348-RJ-45            100.38   2.39   100.38   2.39 ok



Chassis per slot cooling capacity : 49 cfm


Fan tray(s) cooling capacity :

Fan  Model               Ver Cooling  Ambient FanStatus
                             capacity temp
---- ------------------- --- -------- ------- ---------
1    WS-C6K-13SLOT-FAN     1  641 cfm    -   ok

Slot cooling requirement :

Slot CardType            Cooling
---- ------------------- -------
2    WS-X6K-SUP2-2GE      30 cfm
3    WS-X6416-GBIC        30 cfm
4    WS-X6148-GE-TX       30 cfm
5    WS-X6148-GE-TX       30 cfm
9    WS-X6348-RJ-45       30 cfm
10   WS-X6348-RJ-45       30 cfm
12   WS-X6348-RJ-45       30 cfm
13   WS-X6348-RJ-45       30 cfm


Chassis connector rating :  1260.00 Watts ( 30.00 Amps @42V)

Slot connector rating :

Slot CardType            ConnectorRating
                         Watts    A @42V
---- ------------------- -------- ------
2    WS-X6K-SUP2-2GE      1260.00  30.00
3    WS-X6416-GBIC        1260.00  30.00
4    WS-X6148-GE-TX       1260.00  30.00
5    WS-X6148-GE-TX       1260.00  30.00
9    WS-X6348-RJ-45       1260.00  30.00
10   WS-X6348-RJ-45       1260.00  30.00
12   WS-X6348-RJ-45       1260.00  30.00
13   WS-X6348-RJ-45       1260.00  30.00
Agreed - you need to order Qty 1x "WS-C6K-13SLT-FAN2="

Should run you about $450 - which is a drop in the bucket compared to a SUP720!