Advertisement

02.26.2008 at 02:44PM PST, ID: 23195375
[x]
Attachment Details

point to point setup for VOIP and data using Cisco 2811 to Cisco 1721 setup

Asked by markdda in IP Telephony, Network Routers, Voice Over IP

Tags: Cisco, Router, 2800 Series, Setting up data/VOIP on a double Point to point circuit

Hello,

OK, here it goes..
We are installing an Avaya IP Office in our main building(Building A). We have an office in a building 500 feet away (Building B). We have installed a 2 point to point T1's between the buildings. Building B will get IP phones (18 IP Phones). Building A has a Cisco 2811 router with 2 WIC-T1's installed. Building B has a Cisco 1721 router with 2 WIC-T1's Installed. I would like one T1 to carry voice and one T1 to carry data between buildings A & B. My Voice network will be on a completely seperate physical newtork from my data network. What I need is help and advice on setting this up properly. The Voice network will be a 172.x.x.x and data will be 192.x.x.x. The network between the buildings will be 10.0.x.x and 10.1.x.x

Thanks in advance

markStart Free Trial
[+][-]02.28.2008 at 03:21PM PST, ID: 21009293

View this solution now by starting your 7-day free trial. Setting up your free trial is quick, easy, and secure. We will return you to this solution, unlocked, when you're done.

 

About this solution

Zones: IP Telephony, Network Routers, Voice Over IP
Tags: Cisco, Router, 2800 Series, Setting up data/VOIP on a double Point to point circuit
Sign Up Now!
Solution Provided By: lrmoore
Participating Experts: 2
Solution Grade: A
 
 