I have a PRI line connected to Cisco CCME 3845 router and now all my incoming and outgoing lines through PRI is not working. When i check with telecom company they said everything fine from their end and they will send a technician. But i want to make sure everything is fine from the router? How can i check that PRI line is working fine or not by doing telnet to the router. I did a show controller e1 command and please see below the result for the same. My knowledge is not that great on this side.
CCME3845#show controller e1
E1 0/0/0 is down.
Applique type is Channelized E1 - balanced
Receiver has remote alarm.
alarm-trigger is not set
Version info Firmware: 20060623, FPGA: 20, spm_count = 0
Framing is CRC4, Line Code is HDB3, Clock Source is Line.
CRC Threshold is 320. Reported from firmware is 320.
Data in current interval (187 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins