HI I HAVE NT SP6an when logon display this :
STOP: c000021a {Fatal System Error}

The Windows Logon Process system process terminated unexpectedly

With a status of 0x00000080 (0x00000000 0x00000000)

The system has been shut down.

 

Beginning dump of physical memory

Physical memory dump complete.   Contact your system administrator or

technical support group.



I try with nt repair disk but does work.

This Question has been solved and asker verified All Experts Exchange premium technology solutions are available to subscription members.

Subscribe now for full access to Experts Exchange and get

Instant Access to this Solution

  • Plus...
  • 30 Day FREE access, no risk, no obligation
  • Collaborate with the world's top tech experts
  • Unlimited access to our exclusive solution database
  • Never be left without tech help again

Subscribe Now

Asked On
2007-02-12 at 10:26:12ID22159616
Tags

logon

,

windows

,

system

,

terminated

,

unexpectedly

Topic

Windows NT Operating System

Participating Experts
2
Points
125
Comments
4

Trusted by hundreds of thousands everyday for fast, accurate and reliable tech support.

  • "The time we save is the biggest benefit of Experts Exchange to Warner Bros. What could take multiple guys 2 hours or more each to find is accessed in around 15 minutes on Experts Exchange." Mike Kapnisakis, Warner Bros.
  • "Our team likes having a resource that is more secure than just using Google and most experts using this service really know their stuff. It's nice to look here first versus using Google." Dayna Sellner, Lockheed Martin
  • "Anytime that I've been stumped with a problem, 9 out of 10 times Experts Exchange has either the accepted solution or an open discussion of the potential solution to the problem." Kenny Red, eBay Inc.

See what Experts Exchange can do for you.

Got a question?

We've got the answer.

Experts Exchange has been collecting answers to technology questions since 1996…3 million and counting! If you have a question, chances are we already have your answer.

Screenshot of Experts Exchange Knowledgebase

Need individual assistance?

Our experts are ready to help.

If you can't find the exact answer you're looking for, ask our exclusive community of 50,000 experts. You’ll get a personalized answer from a trusted professional.

Screenshot of Experts Exchange Knowledgebase

Want to learn from the best?

Read articles from industry experts.

Thousands of free tech tips, tricks, how-to’s and tutorials are available in our peer reviewed articles section. See for yourself how smart our experts are, no login required.

Screenshot of an Article

Working on a long term project?

Store your work and research.

Save solutions to your questions, answers you’ve discovered through searching plus helpful articles in your personal knowledgebase for easy future access.

Screenshot of Experts Exchange Knowledgebase

Access the answers to your technology questions today.

Subscribe Now

30-day free trial. Register in 60 seconds.

What Makes Experts Exchange Unique?

Members of the expert community talk about why the experience at Experts Exchange is different than what you will find anywhere else.

Trusted by the world's most respected brands.

image of each brand's logo

Faithfully serving IT professionals since 1996.

Experts Exchange Logo

Try it out and discover for yourself.

Subscribe Now

30-day free trial. Register in 60 seconds.

Related Solutions

  1. C000021a (Fatal System Error)
    I keep on getting this error message "C000021a (Fatal System Error). Windows logon process system process terminared unexpectedly" And I cannot logon to NT at all. Please help... email answers to richard.adeolu@jci.com will be greatly appriciated
  2. Error code C000021a
    Upon startup I get the "Blue screen of death" on an NT workstation 4.0 with SP3. The error code is C000021a. Would appreciate any suggestions. The error message is as follows: Stop:c000021a(Fatal System Error) The Windows Logon Process system process terminated u...
  3. STOP: c000021a (Fatal system error)
    I have a machine with Windows NT Workstation 4.0 and SP5, besides other applications. The last thing I did was logon as local administrator and gave local administrator privilegies to an user from the domain, which is a common task. I reboot, and the following error appeared,...
  4. BSOD Stop: C000021a {fatal system error}
    I was updating a BackOffice Small Business Windows NT 4.0 SP 5 to Sp6a and when I rebooted I received the following message: Stop: C000021a {fatal system error} The windows logon process system process terminated unexpectedly with a status of 0X00000080 (0x00000000 0X0000000...
  5. message on bootup - stop c000021a {fatal system e…
    I was installing Windows XP upgrades when my PC did a reboot, but I got the message: stop c000021a {fatal system error} the windows logon process system process terminated unexpectedly. I can F8 to the safe mode selection screen, but none of the selections will allow it to st...
  6. Fatal System Error : The windows logon system process t…
    I have an XP user who will be working and her computer will just go blue and the error reads. stop c000021a {fatal system error} the windows logon process system process terminated unexpectedly Should I reinstall XP with the Repair module or is there another route? Thanks ...

Free Tech Articles

  1. WARNING: 5 Reasons why you should NEVER fix a computer for free.
    It is in our nature to love the puzzle. We are obsessed. The lot of us. We love puzzles. We love the challenge. We thrive on finding the answer. We hate disarray. It bothers us deep in our soul. W...
  2. SCCM OSD Basic troubleshooting
    SCCM 2007 OSD is a fantastic way to deploy operating systems, however, like most things SCCM issues can sometimes be difficult to resolve due to the sheer volume of logs to sift through and the dispe...
  3. Migrate Small Business Server 2003 to Exchange 2010 and Windows 2008 R2
    This guide is intended to provide step by step instructions on how to migrate from Small Business Server 2003 to Windows 2008 R2 with Exchange 2010. For this migration to work you will need the fo...
  4. Create a Win7 Gadget
    This article shows you how to create a simple "Gadget" -- a sort of mini-application supported by Windows 7 and Vista. Gadgets can be dropped anywhere on the desktop to provide instant information, ...
  5. Outlook continually prompting for username and password
    There have been a lot of questions recently regarding Outlook prompting for a username and password whilst using Exchange 2007. There are a few reasons why this would happen and I will try to cover t...
  6. Backup Exchange 2010 Information Store using Windows Backup
    There seems to be quite a lot of confusion around the ability to backup Exchange 2010 using the built in Windows Backup feature. This stems from the omission of this feature prior to Exchange 2007 s...

Cloud Class Webinars

  1. Avoiding Bugs in Microsoft Access
    Alison Balter takes and in-depth look at avoiding bugs in Access. In this webinar you will learn about using the immediate window to debug your applications, invoking the debugger, using breakpoints to troubleshoot, stepping through code, setting the next statement to execute, ...
  2. Top 10 Best New Features in Visio 2010
    Scott Helmers gives live demonstrations of the top 10 new features in Visio 2010. This webinar will teach you how to create compelling diagrams by adding shapes to the page with a single click, linking the shapes in a diagram to data in Excel (or SQL Server, or SharePoint), ...
  3. IT Consultant Business Secrets Revealed
    Michael Munger, Experts Exchange tech pro and IT consultant, pulls back the curtain on his very successful businesses and answers question on every IT consultant and business owner should know about. He shares secrets on what he did to solve the 5 most common problems in IT, ...
  4. Disaster Recovery and Business Continuity
    Quest CTO, Mike Billon, gives an overview of the steps involved in building a dunamic disaster recovery plan. Through case studies and an examination of software/hardware tooles for monitoring and testing, you'll gain a better understandin of where you are, where you want ...
  5. Organize Your Visio Diagrams with Containers and Lists
    Scott Helmers uses cross functional flowcharts, wireframe diagrams, data graphic legends and seating charts to teach you: how to ustilize all three new structured diagram components in Visio 2010, the best practices for organizeing shapes in previous version of Visio, how to organize ...
  6. How to Us Objects, Properties, Events and Methods in Microsoft Access
    Alison Dalter gives an in-depbth look at objects, properties, events and methods in Microsoft Access. In this webinar you will learn about using the object browser, referring to objects, working with properties and methods, working with object variables, understanding the ...

Join the Community

Give a Little. Get a Lot.

Join the community of experts here and help other tech pros by answering question in your area of expertise. You can earn FREE access to all Experts Exchange's premium features and resources.

Join the Community

Answers

 

by: jvuzPosted on 2007-02-13 at 23:29:06ID: 18529272

 

by: NHChatsPosted on 2009-06-04 at 17:27:56ID: 24552631

How to troubleshoot a "STOP 0xC000021A" error

http://support.microsoft.com/kb/156669

The STOP 0xC000021A error occurs when either Winlogon.exe or Csrss.exe fails. When the Windows NT kernel detects that either of these processes has stopped, it stops the system and raises the STOP 0xC000021A error. This error may have several causes. Among them are the following:

    * Mismatched system files have been installed.
    * A Service Pack installation has failed.
    * A backup program that is used to restore a hard disk did not
          correctly restore files that may have been in use.
    * An incompatible third-party program has been installed.

---------------------------------------------------------------------------------------------------

To troubleshoot this problem, you must determine which of these processes failed and why.

To determine which process failed, register Dr. Watson as the default system debugger (if it is not already the default debugger). Dr. Watson for Windows NT logs diagnostic information about process failures to a log file (Drwtsn32.log). Also, you can configure this program to produce memory dump files of failed processes that you can analyze in a debugger to determine why a process fails.

To set up Dr. Watson to trap user-mode program errors, follow these steps:

   1. At a command prompt, type System Root\System32\Drwtsn32.exe -I, and then press ENTER.

      This command configures Dr. Watson as the default system debugger.
   2. At a command prompt, type System Root\System32\Drwtsn32.exe, and then select the following options:
      Append to existing log file
      Create crash dump
      Visual Notification
   3. After the computer restarts from the STOP 0xC000021A error, run Dr. Watson (Drwtsn32.exe).
   4. View the Dr. Watson log to determine what user mode process may be causing the problem.
   5. If the Dr. Watson log does not contain sufficient information to determine the cause of the problem, analyze the User.dmp file to determine the cause of the STOP 0xC000021A error.

      If Dr. Watson did not create a User.dmp file for either Winlogon.exe or Csrss.exe, you may have to use a different tool to generate a memory dump file of the process that fails. For more information, click the following article number to view the article in the Microsoft Knowledge Base:
      241215  (http://support.microsoft.com/kb/241215/ ) How to use the Userdump.exe tool to create a dump file
      Note Follow the instructions in the Knowledge Base article to troubleshoot a process that shuts down with an exception. While you follow these instructions, monitor the following processes to troubleshoot the STOP 0xC000021A error:
          * Winlogon.exe
          * Csrss.exe
      Note Most STOP 0xC000021A errors occur because Winlogon.exe fails. This typically occurs because of a faulty third-party Graphical Identification and Authentication (GINA) DLL. The GINA is a replaceable DLL component that Winlogon.exe loads. The GINA implements the authentication policy of the interactive logon model. The GINA performs all identification and authentication user interactions.

It is very common for certain types of remote control software to replace the default Windows GINA DLL (Msgina.dll). Therefore, a good first step is to examine the system to see if it has a third-party GINA DLL. To do this, locate the following registry key:
HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Winlogon
Value = GinaDLL REG_SZ

    * If the Gina DLL value is present and if it is anything other than Msgina.dll, it probably means that a third-party product has changed this value.
    * If this value is not present, the system uses Msgina.dll as the default GINA DLL.

If this error first occurred after the installation of a new or updated device driver, system service, or third-party program, the new software should be removed or disabled. Contact the manufacturer of the software to see if an update is available. For more information about hardware and software vendor contact information, visit the following Microsoft Web site: -
  http://support.microsoft.com/gp/vendors (http://support.microsoft.com/gp/vendors)  
Last known good configuration
If the previous steps in this article do not resolve the problem, start the computer by using the last known good configuration. To start the computer by using the last known good configuration, follow these steps:Note Because there are several versions of Microsoft Windows, the following steps may be different on your computer. If they are, see your product documentation to complete these steps.

   1. Click Start, and then click Shut Down.
   2. Click Restart, and then click OK.
   3. Press F8 at the indicated time:
          * For an x86-based computer: When a screen of text appears and then disappears , press F8. (The screen of text may include a memory test, lines about the BIOS, and other lines.) There may also be a prompt that tells you when to press F8.
          * For an Itanium architecture-based computer: After you make your selection from the boot menu, press F8. There may be a prompt that tells you when to press F8.
   4. Use the arrow keys to select Last Known Good Configuration, and then press ENTER.

      NUM LOCK must be off before the arrow keys on the numeric keypad will function.
   5. Use the arrow keys to highlight an operating system, and then press ENTER.

Notes

    * Choosing the Last Known Good Configuration startup option provides a way to recover from problems such as a newly added driver that may be incorrect for your hardware. However, it does not solve problems that are caused by corrupted or missing drivers or files.
    * When you choose the Last Known Good Configuration option, only the information in registry key HKLM\System\CurrentControlSet is restored. Any changes you have made in other registry keys remain.

In-place upgrade
If the previous steps in this article do not resolve the problem, perform an in-place upgrade. For more information about how to do this,, click the following article numbers to view the articles in the Microsoft Knowledge Base:
292175  (http://support.microsoft.com/kb/292175/ ) How to perform an in-place upgrade of Windows 2000
315341  (http://support.microsoft.com/kb/315341/ ) How to perform an in-place upgrade (reinstallation) of Windows XP
816579  (http://support.microsoft.com/kb/816579/ ) How to perform an in-place upgrade of Windows Server 2003
Remove incompatible software by using the Recovery Console
If the previous steps in this article do not resolve the problem, remove incompatible software by using the Recovery Console. Complete steps that describe how to do this are beyond the scope of this article. However, you may be able to use the following articles as guidelines for performing this procedure.

20120131-EE-VQP-002

3 Ways to Join

30-Day Free Trial

The Experts

98% positive feedback on 31,087 answers since March 2000. angeliii is a Microsoft Most Valuable Professional for his work with MS SQL Server & Develoment.

He has also proven his knowledge of Visual Basic Programming, PHP Scripting and Oracle Databases.

The Experts

97% positive feedback on 10,752 answers since July 2000. lrmoore has more than 18 years experience in the networking industry.

The six-time Mircosoft MVPs specialties include firewalls, virtual private networking, and network management.

Testimonials

"...and excellent source for support... Kind of like having your very own IT dept." Electriciansnet

Testimonials

"I was apprehensive at signing up at first. However... it has already made my life as an IT administrator much easier." JaCrews

Testimonials

"WOW! You guys have great, active, and knowledgeable people on here." moore50

Business Clients

Business Clients

In the Press

"If you’ve got a question... Experts Exchange can supply an answer.”

In the Press

"...an invaluable aid for both IT professionals and those who require tech support."

In the Press

"where IT professionals provide quick answers on just about any topic"

Business Account Plans

Loading Advertisement...