|
[x]
Posted via EE Mobile
|
||
Search, ask, and monitor your questions on the go with EE Mobile. Visit Experts Exchange from your mobile device and never be out of touch again. |
||
| Question |
|
[x]
Attachment Details
|
||
|
[x]
The Solution Rating System
|
||
With so many solutions, how can you tell which solutions are most likely to help you and which ones are not? To provide you with a tool to use, we rate our solutions based on various elements that most accurately determine if a solution is a quality solution. To explain what factors affect the solution rating, here are the elements we take into consideration when formulating our solution rating.
Your Input Matters If you have any suggestions that you would like to make for our rating system, please ask a question in the Suggestions Zone of Community Support. Thank you! |
||
1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11: 12: 13: 14: 15: 16: 17: 18: 19: 20: 21: 22: 23: 24: 25: 26: 27: 28: 29: 30: 31: 32: 33: 34: 35: 36: 37: 38: 39: 40: 41: 42: 43: 44: 45: 46: 47: 48: 49: 50: 51: 52: 53: 54: 55: 56: 57: 58: 59: 60: 61: 62: 63: 64: 65: 66: 67: 68: 69: 70: 71: |
'********************************************************************************
'Set Service Tag this is the code that doesn't work
'********************************************************************************
Sub Service_Tag
strNameSpace = "root/Dellomci"
Set wshNetwork = CreateObject( "WScript.Network" )
strComputerName = wshNetwork.ComputerName
strClassName = "Dell_SystemSummary"
strKeyName = "Name"
'strServiceTag = ServiceTagTextBox.value ' I have an input box on the hta
strServiceTag = "1234567" 'This is to test input of a dummy service tag
strWQLQuery = "SELECT * FROM " & strClassName & " WHERE " & _
strKeyName & "=" & Chr(34) & strComputerName & Chr(34)
Set colInstances = GetObject("WinMgmts:{impersonationLevel=impersonate}//" & _
strComputerName & "/" & strNameSpace).ExecQuery(strWQLQuery, "WQL", NULL)
For Each objInstance in colInstances
objInstance.Properties_.Item("ServiceTag").Value = strServiceTag
objInstance.Put_
Exit For
Next
Set colInstances = Nothing
'*** If any errors occurred, let the user know
If Err.Number <> 0 Then
Msgbox "Setting the BIOS Service Tag failed."
End If
End Sub
'********************************************************************************
'Set Asset Tag This Code works
'********************************************************************************
Sub Asset_Tag
strNameSpace = "root/Dellomci"
Set wshNetwork = CreateObject( "WScript.Network" )
strComputerName = wshNetwork.ComputerName
strClassName = "Dell_SystemSummary"
strKeyName = "Name"
strAssetTag = AssetTagTextBox.value
'*** WQL Query to retrieve instances of Dell_SystemSummary
strWQLQuery = "SELECT * FROM " & strClassName & " WHERE " & _
strKeyName & "=" & Chr(34) & strComputerName & Chr(34)
'*** Retrieve instances of Dell_Configuration class (there should only be 1 instance).
Set colInstances = GetObject("WinMgmts:{impersonationLevel=impersonate}//" & _
strComputerName & "/" & strNameSpace).ExecQuery(strWQLQuery, "WQL", NULL)
'*** Use only first instance to set asset tag
For Each objInstance in colInstances
'*** Set the new value for the property and save the instance
objInstance.Properties_.Item("AssetTag").Value = strAssetTag
objInstance.Put_
Exit For
Next
Set colInstances = Nothing
'*** If any errors occurred, let the user know
If Err.Number <> 0 Then
Msgbox "Setting the BIOS Asset Tag failed."
End If
strMsg = "Setting Asset Tag to: " & strAssetTag
MsgBox strMsg
End Sub
|
Advertisement
| Hall of Fame |