Hi experts,
I am having a problem synchronizing workspaces in PWA. I go to PWA>Server Settings>Project Workspaces and when i synchronize any site, it gives me the errors below. The first three are from the event log and the last one is from the queue.
Event log:
Event Type: Error
Event Source: Office SharePoint Server
Event Category: Project Server Queue
Event ID: 7704
Date: 4/20/2009
Time: 10:13:35 AM
User: N/A
Computer: <SERVER>
Description:
Standard Information:PSI Entry Point:
Project User:
Correlation Id: 244920b6-bc73-4a5e-8dc1-43
818df78368
PWA Site URL:
http://<server>/PWA
SSP Name: <DB>
PSError: GeneralQueueJobFailed (26000)
A queue job has failed. This is a general error logged by the Project Server Queue everytime a job fails - for effective troubleshooting use this error message with other more specific error messages (if any), the Operations guide (which documents more details about queued jobs) and the trace log (which could provide more detailed context). More information about the failed job follows. GUID of the failed job: e4d505c2-fd65-4f09-8342-12
02df1658c7
. Name of the computer that processed this job: <SERVER> (to debug further, you need to look at the trace log from this computer). Failed job type: ReportingWSSSync. Failed sub-job type: WSSSyncMessageEx. Failed sub-job ID: 1. Stage where sub-job failed: (this is useful when one sub-job has more than one logical processing stages).
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
Event Type: Error
Event Source: Office SharePoint Server
Event Category: Project Server Reporting
Event ID: 7812
Date: 4/20/2009
Time: 10:13:34 AM
User: N/A
Computer: <SERVER>
Description:
Standard Information:PSI Entry Point:
Project User:
Correlation Id: 244920b6-bc73-4a5e-8dc1-43
818df78368
PWA Site URL:
http://<server>/PWA
SSP Name: <DB>
PSError: ReportingWSSSyncMessageFai
led (24016)
RDS: A request to synchronize SharePoint data with Project Server failed.
Message: 'ReportingWSSSyncMessageFa
iled'
Project: ProjectUID='1a0df8e3-9276-
42e0-ac7d-
a68a3053f7
23'. ForceFullSync='False'
Error: RDS failed while trying to sync one or more SP lists. The RDS queue message will be retried.
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
Event Type: Error
Event Source: Office SharePoint Server
Event Category: Project Server Reporting
Event ID: 7795
Date: 4/20/2009
Time: 10:13:34 AM
User: N/A
Computer: <SERVER>
Description:
Standard Information:PSI Entry Point:
Project User:
Correlation Id: 244920b6-bc73-4a5e-8dc1-43
818df78368
PWA Site URL:
http://<server>/PWA
SSP Name: <DB>
PSError: ReportingGetSPWebFailed (24017)
RDS: The attempt to synchronize a project's SharePoint workspace with the reporting database failed
Project: Exception of type 'System.OutOfMemoryExcepti
on' was thrown.
Error: (null)
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
--------------------------
----------
----------
----------
----------
---------
Queue error:
Error summary/areas:
[RDS] Failed to determine the SP Web associated with project _693b0358-c428-4bd0-8d11-c
69ba662d8a
0_.
ReportingGetSPWebFailed
ReportingGetSPWebFailed
ReportingGetSPWebFailed
ReportingGetSPWebFailed
ReportingGetSPWebFailed
ReportingGetSPWebFailed
Reporting message processor failed
ReportingWSSSyncMessageFai
led
ReportingWSSSyncMessageFai
led
ReportingWSSSyncMessageFai
led
ReportingWSSSyncMessageFai
led
ReportingWSSSyncMessageFai
led
ReportingWSSSyncMessageFai
led
Queue
GeneralQueueJobFailed
Error details:
<?xml version="1.0" encoding="utf-16"?>
<errinfo>
<general>
<class name="[RDS] Failed to determine the SP Web associated with project _693b0358-c428-4bd0-8d11-c
69ba662d8a
0_.">
<error id="24017" name="ReportingGetSPWebFai
led" uid="cfa1db49-e7f8-4d77-be
6f-7cd30ee
4c6c5" Error="Exception of type 'System.OutOfMemoryExcepti
on' was thrown." />
<error id="24017" name="ReportingGetSPWebFai
led" uid="e6810197-523a-471e-8e
2b-94f667f
c81fb" Error="Exception of type 'System.OutOfMemoryExcepti
on' was thrown." />
<error id="24017" name="ReportingGetSPWebFai
led" uid="c51e3fd4-f2c7-459e-91
7b-61e52e6
b2041" Error="Exception of type 'System.OutOfMemoryExcepti
on' was thrown." />
<error id="24017" name="ReportingGetSPWebFai
led" uid="06aeff99-e00d-4239-94
97-a1ce7a5
e9c0b" Error="Exception of type 'System.OutOfMemoryExcepti
on' was thrown." />
<error id="24017" name="ReportingGetSPWebFai
led" uid="c64bfaaf-4f94-472b-9f
32-5a55d55
2a77a" Error="Exception of type 'System.OutOfMemoryExcepti
on' was thrown." />
<error id="24017" name="ReportingGetSPWebFai
led" uid="aa25bce0-fb0a-42be-a9
91-9e34f35
8fce7" Error="Exception of type 'System.OutOfMemoryExcepti
on' was thrown." />
</class>
<class name="Reporting message processor failed">
<error id="24016" name="ReportingWSSSyncMess
ageFailed"
uid="a77e2106-31c3-442a-81
d6-183fa79
ea030" QueueMessageBody="ProjectU
ID='693b03
58-c428-4b
d0-8d11-c6
9ba662d8a0
'. ForceFullSync='False'" Error="RDS failed while trying to sync one or more SP lists. The RDS queue message will be retried." />
<error id="24016" name="ReportingWSSSyncMess
ageFailed"
uid="a8162574-2442-47a6-9d
8c-6296424
ef4aa" QueueMessageBody="ProjectU
ID='693b03
58-c428-4b
d0-8d11-c6
9ba662d8a0
'. ForceFullSync='False'" Error="RDS failed while trying to sync one or more SP lists. The RDS queue message will be retried." />
<error id="24016" name="ReportingWSSSyncMess
ageFailed"
uid="3374fa8c-ec90-460a-94
78-05d5465
00df7" QueueMessageBody="ProjectU
ID='693b03
58-c428-4b
d0-8d11-c6
9ba662d8a0
'. ForceFullSync='False'" Error="RDS failed while trying to sync one or more SP lists. The RDS queue message will be retried." />
<error id="24016" name="ReportingWSSSyncMess
ageFailed"
uid="47cbcbc4-7035-4f8f-b6
b9-528cd9e
40d1d" QueueMessageBody="ProjectU
ID='693b03
58-c428-4b
d0-8d11-c6
9ba662d8a0
'. ForceFullSync='False'" Error="RDS failed while trying to sync one or more SP lists. The RDS queue message will be retried." />
<error id="24016" name="ReportingWSSSyncMess
ageFailed"
uid="76745af6-5042-4930-aa
1f-941cd0f
51eb7" QueueMessageBody="ProjectU
ID='693b03
58-c428-4b
d0-8d11-c6
9ba662d8a0
'. ForceFullSync='False'" Error="RDS failed while trying to sync one or more SP lists. The RDS queue message will be retried." />
<error id="24016" name="ReportingWSSSyncMess
ageFailed"
uid="8c894617-8462-45c5-bd
6b-efbb277
59119" QueueMessageBody="ProjectU
ID='693b03
58-c428-4b
d0-8d11-c6
9ba662d8a0
'. ForceFullSync='False'" Error="RDS failed while trying to sync one or more SP lists. The RDS queue message will be retried." />
</class>
<class name="Queue">
<error id="26000" name="GeneralQueueJobFaile
d" uid="405baa00-a121-4e26-b7
fe-8353348
7abb4" JobUID="2b9e4174-beb8-4c35
-b17d-b5cb
668f5918" ComputerName="<SERVER>" GroupType="ReportingWSSSyn
c" MessageType="WSSSyncMessag
eEx" MessageId="1" Stage="" />
</class>
</general>
</errinfo>
--------------------------
----------
----------
----------
----------
---------
Any ideas?
Thanks