I need to mass update user profiles in the AS400 programmically. What is the name of the file and library in order to do this?
Zones: AS400 Programming, ...Date Answered: 10/17/2008 Rating: 8.7 Views: 0
I'm new to  AS.400 environment and DB2/400. New projects are coming through at work which get me to start using .net technologies.  Whats the best way to connect to the As/400 to achieve the fo...
Zones: DB2Date Answered: 07/02/2005 Rating: 7.8 Views: 0
Dear All, I want to reduce the size and restructure the physical file by deleteing the  RRN Number of the deleted records . Please provide  the step by step process of doing the same and at the s...
Zones: AS400 ProgrammingDate Answered: 03/26/2009 Rating: 7.4 Views: 4
I am having issues printing to a receipt printer attached to PC. Printer out put is generated on an AS400 and sent to the printer via remote outq. When the remote outq  is started I see the spool ...
Zones: AS / 400Date Asked: 07/13/2009 Points: 500 Comments: 10
I'm looking for direction to locate the source of connectivity problems we're having with DB2 run off of an IBM I-Series (AS400) running OS400.  I'm trying to find some places to look that I can pa...
Zones: DB2Date Answered: 01/23/2005 Rating: 7.0 Views: 0
I have an AS400 System. Where A DVD Writer (Device type: 6337, Device model: 002 and Device Description: OPT01) is attached. 1. How can I Copy any Data from a CD/ DVD to QGPL Library? 2. How can...
Zones: AS / 400, MainFrame OSDate Answered: 02/24/2008 Rating: 7.0 Views: 0
I need to connect two as400's together to allow for the copying of spooled files from one to another. I would eventually like to schedule something so that this is automatic but one step at a time ...
Zones: AS / 400, ...Date Answered: 03/18/2008 Rating: 6.2 Views: 0
We just installed a new AS400, restored our old system and now the line printer does not seem to have the correct line spacing any longer. The printer is the same printer we had before and I check...
Zones: AS400 Programming, ...Date Answered: 06/15/2008 Rating: 6.8 Views: 4
When trying to send spooled files from one box runing V5R3 to another using V5R1, I get error msg cannot connect to remote system 128.200.0.1. Even though it works the other way around. Is sndTCPsp...
Zones: AS / 400Date Answered: 10/06/2008 Rating: 8.6 Views: 0
The spool files on my system are starting to take up too much DASD.  I know I can go in to each users spool file and clean it up for them, or go into the outq's and do the same thing.  What I want ...
Zones: AS / 400Date Answered: 07/18/2008 Rating: 8.2 Views: 0